Standard Drawings

The Standard Drawings on this website have been adopted by Council for use within the Noosa local government area. Please contact Council if you wish to use a different revision than those on this website.

Addendums to the Standard Drawings must be adhered to meeting the requirements of the Noosa Planning Scheme Policies and Noosa Design Principles:

  • Support Noosa's environmental objectives with plantings that enhance biodiversity.
  • Provide a transport network that caters to the needs of the community and blends into the environment rather than dominating it.
  • Design for pedestrians, cyclists and buses in all road corridor improvements.
  • Design to cater for the aged and disabled community.

Please refer to the following documents:

Roads

Driveways

Std Drawing No. Description Addendum
RS-049(PDF, 66KB) Residential driveways (Plan 1 of 2) Yes
RS-050(PDF, 103KB) Residential driveways (Plan 2 of 2) Yes
RS-051(PDF, 67KB) Heavy duty vehicle crossing Yes
RS-056(PDF, 112KB) Rural Driveway Yes
RS-056 and RS-056.1(PDF, 1MB) Rural Driveway with concrete alternative No

Pathways

Std Drawing No. Description Addendum
RS-065(PDF, 108KB) Concrete pathway construction details Yes

Kerb and channel

Std Drawing No. Description Addendum
RS-080(PDF, 91KB) Kerb and channel profiles No
RS-081(PDF, 79KB) Residential drainage connections No
NSD-9006E(PDF, 551KB) Kerb ramp and pedestrian refuge No

Public utilities

Std Drawing No. Description Addendum
RS-100(PDF, 114KB) Typical service corridors and alignments Yes
RS-101(PDF, 121KB) Typical service conduit sections Yes
RS-103(PDF, 61KB) Optic fibre pit No

Signs

Std Drawing No. Description Addendum
RS-130(PDF, 68KB) Street name sign Yes
RS-131(PDF, 74KB) Traffic sign installation details Yes

Subsoil drains

Std Drawing No. Description Addendum
SD1116(PDF, 284KB) Outlets and cleanouts No

Pavement Extension

Std Drawing No. Description Addendum
RS-170(PDF, 151KB) Trenching and widening No

Public transport

Std Drawing No. Description Addendum
DRG 5-0011(PDF, 263KB) Regular stop - minimum boarding point with existing kerb No
DRG 5-0013(PDF, 250KB) Regular stop - without indented No
DRG 5-0014(PDF, 250KB) Regular stop - with indented No
TL-0019(PDF, 666KB) Bus stop J pole sign Yes
DRG 5-0021(PDF, 254KB) Immediate stop - without indented No
DRG 5-0022(PDF, 254KB) Immediate stop - indented No
RS-182(PDF, 156KB) Concrete Indent Bay Standard crossfall No
RS-183(PDF, 157KB) Concrete Indent Bay Adverse crossfall No

Drainage

Access Chamber

Std. Drawing No. Description Addendum
DS-010(PDF, 65KB) Stormwater access chamber detail - 1500 to 2100 diameter No
DS-015(PDF, 67KB) Manhole frame - Roadway and non-roadway - 1050 to 2100 diameter No
DS-018(PDF, 73KB) Manhole riser details (roadway) No
DS-019(PDF, 78KB) Manhole cover (roadway) 1050 to 2100 diameter No
DS-020(PDF, 93KB) Manhole cover (non roadway) 1050 to 2100 diameter No
DS-021(PDF, 80KB) Manhole cover concrete infill (pedestrian traffic) 1050 to 2100 diameter No
DS-082(PDF, 65KB) Culvert inlet screen No
MR-1307(PDF, 184KB) Access chamber 1050 to 2100 diameter No
MR-1308(PDF, 255KB) Access chamber roof slabs 1050 to 2100 diameter No

Bedding and backfilling

Std. Drawing No. Description Addendum
DS-030(PDF, 195KB) Excavation, bedding and backfilling of stormwater drainage pipes No
DS-031(PDF, 76KB) Excavation, bedding and backfilling precast box culverts No

Sediment control devices

Std. Drawing No. Description Addendum
ESC-01 Rock pads for building sites No
ESC-02 Grated stormwater (field) inlet sediment traps No
ESC-03 Kerb inlet sediment traps No
ESC-04 Sediment fence No
ESC-05 Sediment fence - notes No

Drainage pits

Std. Drawing No. Description Addendum
9223A(PDF, 106KB) Catch pit - kerb entry type No
9223-2(PDF, 63KB) Catch pit lid - environmental message - kerb entry type No
DS-050(PDF, 96KB) Field inlet - Type 1 and type 2 No
DS-060(PDF, 64KB) Kerb inlet - general arrangement Yes
DS-061(PDF, 57KB) Kerb inlet - precast lintel details Yes
DS-062(PDF, 95KB) Kerb inlet - grate and frame Yes
DS-063(PDF, 66KB) Kerb inlet - lip in line general arrangement No
DS-068(PDF, 52KB) Kerb inlet - kerb in line anti ponding Yes
DS-069(PDF, 1MB) Kerb inlet pit - dome top ocver (900 x 600) Yes

Culverts

Std. Drawing No. Description Addendum
MR-1174(PDF, 136KB) RC Box culvert - construction of end structures H = 150 - 600 No
MR-1243(PDF, 673KB) Precast headwall (1 of 2) No
MR-1303(PDF, 275KB) RC Box culvert - construction of reinforced concrete wingwalls and headwalls No
MR-1304(PDF, 542KB) Construction of reinforced concrete wingwalls and aprons for pipe diameter up to 2400 No
MR-1305(PDF, 314KB) General arrangement and installation of wingwalls and aprons for pipe diameter 375-675 diameter No
MR-1316(PDF, 216KB) General arrangement and installation of precast units Yes
MR-1317 Rev H(PDF, 357KB) Construction of bases with nibs and aprons Yes
MR-1318 Rev G(PDF, 335KB) Construction of bases with recesses and aprons Yes
MR-1319 Rev I(PDF, 209KB) Construction of reinforced wingwalls and RC headwalls H + 750 - 2400 No
MR-1320 Rev C(PDF, 149KB) Crown unit holding down anchors No

Landscaping

Planting

Std. Drawing No. Description Addendum
GS-010(PDF, 95KB) Street tree planting with root barriers No
GS-011(PDF, 110KB) Street tree planting - wide median Yes
GS-012(PDF, 100KB) Street tree planting - narrow median Yes

Fencing

Std. Drawing No. Description Addendum
MR-1603(PDF, 317KB) Koala proof fence and gate No
GS-041(PDF, 112KB) Chainwire security fence Yes
GS-042(PDF, 69KB) Log barrier and alternative hardwood timber bollard Yes
GS-043(PDF, 89KB) Locking rail No
GS-044(PDF, 62KB) Tubular steel fence with & without chain wire Yes
GS-045(PDF, 72KB) Welded mesh fencing and control fence Yes
GS-046(PDF, 50KB) Dune protection No
Bin-01(PDF, 626KB) Waste bin Yes

Addendums

Driveways

Std. Drawing No. Description
RS-049(PDF, 66KB) provide for min 2.0m wide concrete pathway at max 2.5% cross fall
RS-050(PDF, 103KB) provide for min 2.0m wide concrete pathway at max 2.5% cross fall
RS-051(PDF, 67KB) General Type Preferred. Provide for min 2.0m wide concrete pathway at max 2.5% crossfall.
RS-056(PDF, 112KB) Noosa Council has not adopted Revision G. Please use Revision F available above under Roads.
Min. 1.5m of driveway abutting into existing road edge to be flexible pavement
RS-056 and RS056.1(PDF, 1MB) Rural driveway (Concrete Alternative)

Pathways

Std. Drawing No. Description
RS-065(PDF, 108KB) Pathway widths:
Off road trunk pathways – minimum 2.5m, desirable 3.0m or full width in commercial precinct. Absolute minimum 1.5m at squeeze points only.
  • Arterial - minimum 2.5m, desirable 3.0m
  • Distributor - minimum 2.0m, desirable 3.0m
  • Collector - minimum 1.8m, desirable 2.4m
  • Local - minimum 1.5m, desirable 2.0m.
Concrete specification:
  • 1.5m - 2.5m wide pathway – 32Mpa, 125mm, SL72 mesh centrally
  • >2.5m wide pathway - 32Mpa, 150mm, SL82 mesh centrally

Utilities

Std. Drawing No. Description
RS-100(PDF, 114KB) Typical service corridors and alignments are for new developments only. In brownfield sites maintain existing alignments where necessary.

Signs

Std. Drawing No. Description
RS-130(PDF, 68KB) White lettering on Noosa green background. No logo. Street numbers optional. If street numbers are not used, sign plate to be 150mm high with 100mmm high lettering.
RS-131(PDF, 74KB) Sign posts to be installed using typical post anchor or Loc-socket only.
IS 10 J pole sign posts to be installed using V-sockets or Lock-sockets. When adjacent to pathway the mounted height of the sign is 2.5m to allow for cyclists.

Sediment Control

Std. Drawing No. Description
IECA REFER to International Erosion Control Association

Drainage pits

Std. Drawing No. Description
DS-060, DS-061, DS-062, DS-063, DS-068 Preferred Kerb inlet is Noosa 9223 with environmental message where possible.Inlet capacity charts are available on request

Landscape

Std. Drawing No. Description
GS-011 and GS-012 Median kerb type to be SM3 with 300mm wide coloured concrete backing strip
GS-041, GS-044, GS045 Black only PVC mesh, posts to be painted black or as specified by Council.